             AstroNova AstroNova
- 
             AOiP AOiP
- 
             ADASH ADASH
- 
             Amptek Amptek
- 
             Automatic Research Automatic Research
- 
             AWSensors AWSensors
- 
             AARONIA AG AARONIA AG
- 
             BASI BASI
- 
             CALMET CALMET
- 
             DV Power DV Power
- 
             DANATRONICS DANATRONICS
- 
             Dioxide Materials Dioxide Materials
- 
             ED & D ED & D
- 
             ELVEFLOW ELVEFLOW
- 
             ECH ECH
- 
             Elsys Elsys
- 
             EA Technology EA Technology
- 
             Enapter Enapter
- 
             Electrothermal Electrothermal
- 
             Enervac Enervac
- 
             EL-CELL EL-CELL
- 
             ENERGY SUPPORT ENERGY SUPPORT
- 
             FASTEC FASTEC
- 
             GMW GMW
- 
             Gaskatel Gaskatel
- 
             GIUSSANI GIUSSANI
- 
             Globecore Globecore
- 
             GRZ GRZ
- 
             HVPD HVPD
- 
             HIGH SENSE SOLUTIONSHTW HIGH SENSE SOLUTIONSHTW
- 
             IVIUM IVIUM
- 
             Ida Ida
- 
             Instytut Fotonowy Instytut Fotonowy
- 
             JGG JGG
- 
             Jacomex Jacomex
- 
             Jenway Jenway
- 
             Kocos Kocos
- 
             KEHUA TECH KEHUA TECH
- 
             micrux micrux
- 
             Metrel Metrel
- 
             Microrad Microrad
- 
             METERTEST METERTEST
- 
             ndb ndb
- 
             Norecs Norecs
- 
             Novocontrol Novocontrol
- 
             Neware Neware
- 
             OKOndt Group OKOndt Group
- 
             OZM OZM
- 
             Pine Research Pine Research
- 
             Pinflow Pinflow
- 
             Redoxme Redoxme
- 
             SATIR SATIR
- 
             Sonel Sonel
- 
             Serstech Serstech
- 
             SDT SDT
- 
             SENSIA SENSIA
- 
             SIKA SIKA
- 
             SMC SMC
- 
             TANDELTA TANDELTA
- 
             TENTECH TENTECH
- 
             Turnkey Instruments Turnkey Instruments
- 
             VacCoat VacCoat
- 
             Zurich Instruments Zurich Instruments
- AstroNova
- AOiP
- ADASH
- Amptek
- Automatic Research
- AWSensors
- AARONIA AG
- BASI
- CALMET
- DV Power
- DANATRONICS
- Dioxide Materials
- ED & D
- ELVEFLOW
- ECH
- Elsys
- EA Technology
- Enapter
- Electrothermal
- Enervac
- EL-CELL
- ENERGY SUPPORT
- FASTEC
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GRZ
- HVPD
- HIGH SENSE SOLUTIONSHTW
- IVIUM
- Ida
- Instytut Fotonowy
- JGG
- Jacomex
- Jenway
- Kocos
- KEHUA TECH
- micrux
- Metrel
- Microrad
- METERTEST
- ndb
- Norecs
- Novocontrol
- Neware
- OKOndt Group
- OZM
- Pine Research
- Pinflow
- Redoxme
- SATIR
- Sonel
- Serstech
- SDT
- SENSIA
- SIKA
- SMC
- TANDELTA
- TENTECH
- Turnkey Instruments
- VacCoat
- Zurich Instruments
BIO AV 火焰光度計
BIO AV Flame Photometer 型號:BIO AV- 
        BWB BIO AV 是受歡迎的 BWB BIO 的分支。精簡化的菜單結構以及增強Li檢測的能力使其成為 BWB 系列中受歡迎的新成員。能再相同的稀釋度(從 1:6 到 1:100)的情況下同時校準和測量Li、Na、K,從而簡化了許多實驗室的步驟。如果使用者希望輕鬆測量不同的樣品類型,我們保留了輸入和儲存兩個由使用者自行定義校準曲線的功能。 當使用 BWB FP-PC 應用程式連接到 PC 時,使用者可以建立 .pdf 檔案、.csv 檔案、資料展示和包含所有關鍵分析資料的報告。FP-PC 軟體使您能夠檢視與編輯校準曲線,還允許設定自動流體處理系統( AFHS),該系統最初設計為專門與 BIO 裝置配合使用。 對於特定嚴格的測試實驗室中不允許使用 PC 或資料擷取的限制,配置的印表機提供您紙本的數據取得途徑。印表機採用環保列印墨水,字元捕捉壽命最低為10年。該印表機也與其他現成的紙材相容。 無疑的BWB BIO 是當今研究實驗室的必備儀器,其直觀且友好的使用者操作介面突破語言的隔閡,對各個層級的使用者都具有吸引力。 為了提高準確性和再現性,可以選擇使用銫或鋰作為內參比系統 (IRS),作為內標來調整校準和測量過程中的微小變化。 產品特點: - 針對使用者分析元素作專門配置。
- 「IRS」(內部參考標準)銫或鋰選項。
- 單點校準校正。
- 內部參考標準。
- 提供個元素的 10,000 ppm 校準標準。
- 分析 Li 以及 Na 和 K。
- 操作員獨立確定結果。
- 先進的自動確定結果。
- 採用環保墨水的一體式印表機。
- BIO AV 上的 IQ、OQ、PQ 基於網路的認證標準,適用於所有 BWB 火焰光度計設備
 
- 
        Sample rate 2 – 3.5ml/min Tubing materials Silicone and Tygon® Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D) For Safety reasons the Flame 
 photometer requires1m of
 unobstructed space above to allow dissipation of
 heat from the chimney.Instrument size BIO AV Flame Photometer 
 51cm (H) x 39cm (W) x 35cm (D)
 (20in x 15in x 14in)Shipping 
 65cm (H) x 49cm (W) x 43cm (D)
 (25in x 19in x 17in)Weight BIO AV Flame Photometer 14kg (30.8lbs) Shipping 25kg (55.1lbs) Specificity Na/K/Li = <1% to each other when 
 equal in concentration at <100ppmOptimal range Multi-point calibration Na – 0.0043 – 300mmol/l* K – 0.0013 – 200mmol/* Li – 0.0072 – 20mmol/l* *With required Dilution Ratios Reproducibility <1% Coefficient of variability for 20 consecutive 
 samples over ten minutes at concentrations of
 100ppm equivalent or less.
 (After instrument stabilisation).Limit of detection (LOD) and 
 limit of quantification (LOQ)LOD LOQ Na – 0.0013mmol/l Na – 0.0043mmol/l K – 0.0005mmol/l K – 0.0013mmol/l Li – 0.003mmol/l Li – 0.0072mmol/l Time to stability Less than 15 seconds after sample 
 is introduced into the flameIons measured Na, K, and Li Recommended minimum warm up 
 time based on ambient temperature21°C – 25 minutes Power requirements 100V – 250V AC at 50 or 60Hz Fuel requirement Propane, Butane or Natural Gas 
 * regulated to 19Bar. Flow rate of 0.4l/min*with modifications. BWB Technologies 
 recommends either Propane or
 Butane for optimum results.Readout LCD, four line, alpha numeric, back lit. 
- 
        - Specially configured for a range of user interests
- “IRS” (Internal Reference Standard) caesium or lithium option
- Single point calibration correction
- Internal reference standards
- 10K ppm calibration standards for each element
- Analysing Li along with Na and K
- Operator independent determination of results
- Advanced automated determination of results
- Integrated printer with environmentally friendly ink
- IQ, OQ, PQ web-based certification standard on BIO AV and available on all BWB FES units
 
- 
        Sample rate 2 – 3.5ml/min Tubing materials Silicone and Tygon® Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D) For Safety reasons the Flame 
 photometer requires1m of
 unobstructed space above to allow dissipation of
 heat from the chimney.Instrument size BIO AV Flame Photometer 
 51cm (H) x 39cm (W) x 35cm (D)
 (20in x 15in x 14in)Shipping 
 65cm (H) x 49cm (W) x 43cm (D)
 (25in x 19in x 17in)Weight BIO AV Flame Photometer 14kg (30.8lbs) Shipping 25kg (55.1lbs) Specificity Na/K/Li = <1% to each other when 
 equal in concentration at <100ppmOptimal range Multi-point calibration Na – 0.0043 – 300mmol/l* K – 0.0013 – 200mmol/* Li – 0.0072 – 20mmol/l* *With required Dilution Ratios Reproducibility <1% Coefficient of variability for 20 consecutive 
 samples over ten minutes at concentrations of
 100ppm equivalent or less.
 (After instrument stabilisation).Limit of detection (LOD) and 
 limit of quantification (LOQ)LOD LOQ Na – 0.0013mmol/l Na – 0.0043mmol/l K – 0.0005mmol/l K – 0.0013mmol/l Li – 0.003mmol/l Li – 0.0072mmol/l Time to stability Less than 15 seconds after sample 
 is introduced into the flameIons measured Na, K, and Li Recommended minimum warm up 
 time based on ambient temperature21°C – 25 minutes Power requirements 100V – 250V AC at 50 or 60Hz Fuel requirement Propane, Butane or Natural Gas 
 * regulated to 19Bar. Flow rate of 0.4l/min*with modifications. BWB Technologies 
 recommends either Propane or
 Butane for optimum results.Readout LCD, four line, alpha numeric, back lit. 

 
 
 
 
 
            