選擇品牌

-
AARONIA AG
-
ADASH
-
Amptek
-
AOiP
-
AstroNova
-
Automatic Research
-
AWSensors
-
BASI
-
BRS
-
CALMET
-
CHECKLINE
-
Cmc
-
CTRL
-
DANATRONICS
-
DV Power
-
EA Technology
-
ECH
-
EL-CELL
-
Electrothermal
-
Elsys
-
ELVEFLOW
-
Enapter
-
ENERGY SUPPORT
-
Enervac
-
FASTEC
-
Gaskatel
-
GE
-
GIUSSANI
-
Globecore
-
GMW
-
GREENLIGHT
-
GRZ
-
HIGH SENSE SOLUTIONSHTW
-
HTW
-
HUBER
-
HVPD
-
Ida
-
Instytut Fotonowy
-
IVIUM
-
Jacomex
-
Jenway
-
JGG
-
KEHUA TECH
-
Labdex
-
Labnics
-
LIQUID
-
METERTEST
-
Metrel
-
Microrad
-
micrux
-
ndb
-
Neware
-
Norecs
-
Novocontrol
-
OKOndt Group
-
OZM
-
Pine Research
-
Pinflow
-
Redoxme
-
SATIR
-
SDT
-
Serstech
-
VacCoat
-
Zurich
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- Automatic Research
- AWSensors
- BASI
- BRS
- CALMET
- CHECKLINE
- Cmc
- CTRL
- DANATRONICS
- DV Power
- EA Technology
- ECH
- EL-CELL
- Electrothermal
- Elsys
- ELVEFLOW
- Enapter
- ENERGY SUPPORT
- Enervac
- FASTEC
- Gaskatel
- GE
- GIUSSANI
- Globecore
- GMW
- GREENLIGHT
- GRZ
- HIGH SENSE SOLUTIONSHTW
- HTW
- HUBER
- HVPD
- Ida
- Instytut Fotonowy
- IVIUM
- Jacomex
- Jenway
- JGG
- KEHUA TECH
- Labdex
- Labnics
- LIQUID
- METERTEST
- Metrel
- Microrad
- micrux
- ndb
- Neware
- Norecs
- Novocontrol
- OKOndt Group
- OZM
- Pine Research
- Pinflow
- Redoxme
- SATIR
- SDT
- Serstech
- VacCoat
- Zurich
CMP-200
Digital Clamp-on AC leakage current meter 型號:CMP-200
The CMP-200 digital clamp meter has been designed for clamp measurements of AC leakage current. AC current measurement up to 200 A.
- high resolution (0,1 mA),
- three measuring ranges: 200 mA, 2 A, 200 A.
-
The most important features of CMP-200 are:
- display LCD 3½ digits (max 1999),
- white LED backlight,
- internal diameter clamp approx. 30 mm (1,2"),
- DATA HOLD function, for holding measured values.
- MAX function,
- AUTO-OFF function,
- double molded casing.
-
AC current measurement
Range Resolution Accuracy 199,9 mA 0,1 mA ±(5% m.v + 8 dgt) 1,999 A 0,001 A ±(5% m.v. + 10 dgt) 199,9 A 0,1 A ±(2,5% m.v. + 10 dgt) „m.v.”- measured value
Electric security:
- type of insulation: double, according to EN 61010 - 1 And IEC 61557
- measurement category: CAT II 600 V acc. to EN 61010 - 1:2004
- protection class acc. to EN 60529: IP40
Other technical data:
- power supply: 1,5 V AAA battery (2 pcs.)
- over range indication: 0L displayed
- sampling rate: 2 times per second
- display: 1999 counts LCD, 3½ digits
- dimensions: 182 x 61 x 34 mm
- weight (including batteries): 225 g
- auto power OFF: 15 min.
- accordance with following standards: EN 61010 - 1:2004, EN 61010 - 2 - 032
- quality standard: ISO 9001
Rated operational conditions:
- operating temperature and humidity: 0...+30°C (max 90%), 30...40°C (max 75%), 40...50°C (max 45%)
- storage temperature: -25...+60°C max <90%
- operating altitude: max 3000 m