             AstroNova AstroNova
- 
             AOiP AOiP
- 
             ADASH ADASH
- 
             Amptek Amptek
- 
             Automatic Research Automatic Research
- 
             AWSensors AWSensors
- 
             AARONIA AG AARONIA AG
- 
             BASI BASI
- 
             CALMET CALMET
- 
             DV Power DV Power
- 
             DANATRONICS DANATRONICS
- 
             Dioxide Materials Dioxide Materials
- 
             ED & D ED & D
- 
             ELVEFLOW ELVEFLOW
- 
             ECH ECH
- 
             Elsys Elsys
- 
             EA Technology EA Technology
- 
             Enapter Enapter
- 
             Electrothermal Electrothermal
- 
             Enervac Enervac
- 
             EL-CELL EL-CELL
- 
             ENERGY SUPPORT ENERGY SUPPORT
- 
             FASTEC FASTEC
- 
             GMW GMW
- 
             Gaskatel Gaskatel
- 
             GIUSSANI GIUSSANI
- 
             Globecore Globecore
- 
             GRZ GRZ
- 
             HVPD HVPD
- 
             HIGH SENSE SOLUTIONSHTW HIGH SENSE SOLUTIONSHTW
- 
             IVIUM IVIUM
- 
             Ida Ida
- 
             Instytut Fotonowy Instytut Fotonowy
- 
             JGG JGG
- 
             Jacomex Jacomex
- 
             Jenway Jenway
- 
             Kocos Kocos
- 
             KEHUA TECH KEHUA TECH
- 
             micrux micrux
- 
             Metrel Metrel
- 
             Microrad Microrad
- 
             METERTEST METERTEST
- 
             ndb ndb
- 
             Norecs Norecs
- 
             Novocontrol Novocontrol
- 
             Neware Neware
- 
             OKOndt Group OKOndt Group
- 
             OZM OZM
- 
             Pine Research Pine Research
- 
             Pinflow Pinflow
- 
             Redoxme Redoxme
- 
             SATIR SATIR
- 
             Sonel Sonel
- 
             Serstech Serstech
- 
             SDT SDT
- 
             SENSIA SENSIA
- 
             SIKA SIKA
- 
             SMC SMC
- 
             TANDELTA TANDELTA
- 
             TENTECH TENTECH
- 
             Turnkey Instruments Turnkey Instruments
- 
             VacCoat VacCoat
- 
             Zurich Instruments Zurich Instruments
- AstroNova
- AOiP
- ADASH
- Amptek
- Automatic Research
- AWSensors
- AARONIA AG
- BASI
- CALMET
- DV Power
- DANATRONICS
- Dioxide Materials
- ED & D
- ELVEFLOW
- ECH
- Elsys
- EA Technology
- Enapter
- Electrothermal
- Enervac
- EL-CELL
- ENERGY SUPPORT
- FASTEC
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GRZ
- HVPD
- HIGH SENSE SOLUTIONSHTW
- IVIUM
- Ida
- Instytut Fotonowy
- JGG
- Jacomex
- Jenway
- Kocos
- KEHUA TECH
- micrux
- Metrel
- Microrad
- METERTEST
- ndb
- Norecs
- Novocontrol
- Neware
- OKOndt Group
- OZM
- Pine Research
- Pinflow
- Redoxme
- SATIR
- Sonel
- Serstech
- SDT
- SENSIA
- SIKA
- SMC
- TANDELTA
- TENTECH
- Turnkey Instruments
- VacCoat
- Zurich Instruments
TE30 測試儀軟體
TE30 型號:Software for TE30 testervLarge Touchscreen with display and keyboard functions for easy operation enables
- measure of power network parameters: voltages U1, U2, U3, U12, U23, U31, UN, currents I1, I2, I3, IN,frequency f,
 phase angles j1, j2, j3,
 power factors PF1, PF2, PF3, SPF,
 factors sinj1, sinj2, sinj3, Ssinj, tgj1, tgj2, tgj3, Stgj,
 angles between voltages ÐU12, ÐU23, ÐU31, powers P1, P2, P3, SP, Q1, Q2, Q3, SQ, S1, S2, S3, SS,
 
- visualization of measurement results in form of:table, vectors, trend chart,
 oscilloscope (waveform) or
 bar chart (harmonics of U, I, P, Q).
- 
        Specifications for a power network analyser Parameter Range Error limits 1)2)3)4) class 0.05 class 0.1 Voltage (Direct) 0.05…600V ±0.05% 5) ±0.1% 5) Voltage (VoltLiteWire 40kV) 0.1…40kV ±0.1%±Em Current (Direct) 0.01…12A 
 0.001…0.01A±0.05% 
 ±0.05%*±0.1% 
 ±0.1%*Current (Clamps CT10AC) 0.1…12A 
 0.003…0.1A±0.2% 
 ±0.2%*Current (Clamps CT100AC) 0.1…120A 
 0.01…0.1A±0.2% 
 ±0.2%*Current (Clamps CT1000AC) 10…1200A 
 0.3…10A±0.2% 
 ±0.2%*Current (Flexible Clamps FCT3000AC.B) 0.3…30A/3…300A/30…3000A ±0.1%±Em Current (AmpLiteWire 2000A) 1…2000A ±0.1%±Em Power and energy (Direct) 0.01…12A / 10…600V 
 0.001…0.01A / 10…600V±0.05% 
 ±0.05%*±0.1% 
 ±0.1%*Power and energy (Clamps CT10AC) 0.1…12A / 10…600V 
 0.01…0.1A / 10…600V±0.2% 
 ±0.2%*Power and energy (Clamps CT100AC) 0.1…120A / 10…600V 
 0.01…0.1A / 10…600V±0.2% 
 ±0.2%*Power and energy (Clamps CT1000AC) 10…1200A / 10…600V 
 1…10A / 10…600V±0.2% 
 ±0.2%*Power and energy (Flexible Clamps FCT3000AC.B) 0.3…30A/3…300A/30…3000A / 10…600V ±0.1%±Em Power and energy (VoltLiteWire 40kV + AmpLiteWire 2000A) 1…2000A / 0.5…40kV ±0.1%±Em Frequency 40…70Hz ±0.01Hz Phase shift (Direct) -180…+180° ±0.02° 5)6) ±0.04° 5)6) Phase shift (Clamps) -180…+180° ±0.1° 5)7) Power factor cosj and sinj 0…±1 ±0.001 5)6)7) Temperature coefficient (Direct) 0.005% per 1°C in range -10…+50°C Time stability (Direct) Short term [1h] = 0.01%, long term [1 year] = 0.03% 1) % - related to the measuring value, %* - related to the measuring range final value (is underlined) 
 2) error limits include reference uncertainty of standards, stability in 12 months, influence quantities (ambient temperature in
 range +20…+26°C, humidity and power supply voltage in range 50…450V, frequency in range 45…65Hz)
 3) Em – sensor basic error, Em=1%+0.1%* (Flexible Clamps FCT3000AC), Em=2%+0.2%* (VoltLiteWire 40kV and AmpLiteWire 2000A)
 4) power and energy errors related to apparent power
 5) in voltage range 10…600V (Direct)
 6) in current range 0.01…12A (Direct)
 7) in current range: 0.1A…12A (Clamps CT10AC), 0.1A…120A (Clamps CT100AC), 10A…1200A (Clamps CT1000AC)General parameters Weight and dimensions (width x height x depth) 2kg (with internal battery) and (270x245x90)mm Power supply 50…450V / 47...63Hz / 15VA or 
 replaceable batteries Ni-MH 5xAA 1.2V / 2600mAh / 2hSafety: Isolation protection and Measurement Category IEC 61010-1 and 300V CAT III Degree of protection Device is placed in IP67 housing Operation / storage temperature -10…+50°C / -20…+60°C Operation / storage relative humidity <90% @ +0...+30°C and <75% @ +30...+50°C / <95% @ 0...+50°C 

 
 
 
 
 
            