 
    - 
             AstroNova AstroNova
- 
             AOiP AOiP
- 
             ADASH ADASH
- 
             Amptek Amptek
- 
             Automatic Research Automatic Research
- 
             AWSensors AWSensors
- 
             AARONIA AG AARONIA AG
- 
             BASI BASI
- 
             CALMET CALMET
- 
             DV Power DV Power
- 
             DANATRONICS DANATRONICS
- 
             Dioxide Materials Dioxide Materials
- 
             ED & D ED & D
- 
             ELVEFLOW ELVEFLOW
- 
             ECH ECH
- 
             Elsys Elsys
- 
             EA Technology EA Technology
- 
             Enapter Enapter
- 
             Electrothermal Electrothermal
- 
             Enervac Enervac
- 
             EL-CELL EL-CELL
- 
             ENERGY SUPPORT ENERGY SUPPORT
- 
             FASTEC FASTEC
- 
             GMW GMW
- 
             Gaskatel Gaskatel
- 
             GIUSSANI GIUSSANI
- 
             Globecore Globecore
- 
             GRZ GRZ
- 
             HVPD HVPD
- 
             HIGH SENSE SOLUTIONSHTW HIGH SENSE SOLUTIONSHTW
- 
             IVIUM IVIUM
- 
             Ida Ida
- 
             Instytut Fotonowy Instytut Fotonowy
- 
             JGG JGG
- 
             Jacomex Jacomex
- 
             Jenway Jenway
- 
             Kocos Kocos
- 
             KEHUA TECH KEHUA TECH
- 
             micrux micrux
- 
             Metrel Metrel
- 
             Microrad Microrad
- 
             METERTEST METERTEST
- 
             ndb ndb
- 
             Norecs Norecs
- 
             Novocontrol Novocontrol
- 
             Neware Neware
- 
             OKOndt Group OKOndt Group
- 
             OZM OZM
- 
             Pine Research Pine Research
- 
             Pinflow Pinflow
- 
             Redoxme Redoxme
- 
             SATIR SATIR
- 
             Sonel Sonel
- 
             Serstech Serstech
- 
             SDT SDT
- 
             SENSIA SENSIA
- 
             SIKA SIKA
- 
             SMC SMC
- 
             TANDELTA TANDELTA
- 
             TENTECH TENTECH
- 
             Turnkey Instruments Turnkey Instruments
- 
             VacCoat VacCoat
- 
             Zurich Instruments Zurich Instruments
- AstroNova
- AOiP
- ADASH
- Amptek
- Automatic Research
- AWSensors
- AARONIA AG
- BASI
- CALMET
- DV Power
- DANATRONICS
- Dioxide Materials
- ED & D
- ELVEFLOW
- ECH
- Elsys
- EA Technology
- Enapter
- Electrothermal
- Enervac
- EL-CELL
- ENERGY SUPPORT
- FASTEC
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GRZ
- HVPD
- HIGH SENSE SOLUTIONSHTW
- IVIUM
- Ida
- Instytut Fotonowy
- JGG
- Jacomex
- Jenway
- Kocos
- KEHUA TECH
- micrux
- Metrel
- Microrad
- METERTEST
- ndb
- Norecs
- Novocontrol
- Neware
- OKOndt Group
- OZM
- Pine Research
- Pinflow
- Redoxme
- SATIR
- Sonel
- Serstech
- SDT
- SENSIA
- SIKA
- SMC
- TANDELTA
- TENTECH
- Turnkey Instruments
- VacCoat
- Zurich Instruments
- 
        專門對合成和生物燃料生產線常見的四種原子進行可靠、準確的分析。 在這個強大且不斷發展的全球產業結構中,與合成燃料或生物燃料生產的相關行業扮演著重要的角色。對於這類的衍生產品,BWB Technologies 提供了一種混合火焰光度計,我們將其命名為 Syn Fuels。 BWB SYN FUELS 火焰光度計是第一款也是唯一一款能夠同時偵測並顯示所有 4 種元素的 4 通道火焰光度計。BWB SYN FUELS 是一款高品質、高性能的儀器,採用現代技術來提高準確性和穩定性,同時顯著縮短分析時間。 BWB SYN FUELS 火焰光度計的流體處理部分,採用了專有的工程熱塑性塑料,這些熱塑性塑料具有高度耐化學性,可承受合成燃料生產設施中使用的溶劑。 我們在全球的客戶經過統計,大多數是甜菜或甘蔗精煉廠購買 BWB Sugar ,而生物轉化工廠則購買 Syn Fuels FES。 產品特點: - 同時偵測並顯示所有 4 種分析元素。
- 「IRS」(內部參考標準)銫或鋰選項。
- 直覺的使用者介面真正易於使用。
- 顯示提示引導操作。
- 內建空氣壓縮機。
- 含括基本儀器所需器具,可協助您入門。
- 透過電腦連結共享數據。
- 操作員獨立確定結果。
- 使用者可選4 個測量單位。
- 使用者可選擇小數位。
- 選購的整合式印表機使用現成的紙張(新增選項)。
- 提供 IQ、OQ、PQ 基於網路的認證。
- 校正 Ca 以消除高濃度 Na 的干擾。
 
- 
        Sample rate 2 – 3.5ml/min Tubing materials PTFE and Teflon Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D) 
 *For Safety reasons the Flame
 photometer requires 1m of
 unobstructed space above
 to allow dissipation of heat from the chimney.Instrument size Syn Fuels Flame Photometer 
 51cm (H) x 39cm (W) x 35cm (D)
 (20in x 15in x 14in)Shipping 
 65cm (H) x 49cm (W) x 43cm (D)
 (25in x 19in x 17in)Weight Syn Fuels Flame Photometer – 14kg (30.8lbs) Shipping – 25kg (55.1lbs) Power requirements 100V – 250V AC at 50 or 60Hz Readout LCD, four line, alpha numeric, back lit. Optimal range Single point calibration Na 0.1 – 60ppm K 0.05 – 100ppm Li 0.05 – 50ppm Ca 1.0 – 100ppm Multi Point Calibration Na 0.1 – 1000ppm K 0.05 – 1000ppm Li 0.05 – 1000ppm Ca 1.0 – 1000ppm Reproducibility <1% Coefficient of variability for 20 consecutive 
 samples over ten minutes at concentrations of 100ppm or less.
 (After instrument stabilisation).Specificity Na/K/Li = <1% to each other when 
 equal in concentration at <100ppmLimit of detection (LOD) and limit 
 of quantification (LOQ) displayedLOD LOQ Na – 0.03ppm Na – 0.1ppm K – 0.02ppm K – 0.05ppm Li – 0.02ppm Li – 0.05ppm Ca – 0.3ppm Ca – 1ppm Time to stability Less than 15 seconds after sample is introduced 
 into the flameIons measured Simultaneous measurement of Na, K, Li, Ca Interfaces USB 0-2.5 volt output (based on sample 
 concentration linked to element of users choice)
 Optional 4-20mA output in place of the above
 Optional integrated printer.CSV and .PDF generated
 reports and files via FP-PC software
 Collection Cup fitted as standard allowing live readingRecommended minimum warm uptime based 
 on ambient temperature21°C – 25 minutes Fuel requirement Propane, Butane or Natural Gas* regulated to 19Bar. 
 Flow rate of 0.4l/min*with modifications. BWB Technologies 
 recommends either Propane or Butane for optimum results.
- 
        - Simultaneous detection and display of all 4 atoms of interest
- “IRS” (Internal Reference Standard) caesium or lithium option
- Intuitive user interface for true ease of use
- Display prompts step by step operation
- Built-in air compressor
- Solutions and labware included
- Data sharing via pc link
- Operator independent determination of results
- 4 user selectable units of measure
- User selectable decimal places
- Optional integrated printer uses readily available paper (added option)
- IQ, OQ, PQ web-based certification available
- Correction of Ca for the interference from high levels of Na
 
- 
        Sample rate 2 – 3.5ml/min Tubing materials PTFE and Teflon Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D) 
 *For Safety reasons the Flame
 photometer requires 1m of
 unobstructed space above
 to allow dissipation of heat from the chimney.Instrument size Syn Fuels Flame Photometer 
 51cm (H) x 39cm (W) x 35cm (D)
 (20in x 15in x 14in)Shipping 
 65cm (H) x 49cm (W) x 43cm (D)
 (25in x 19in x 17in)Weight Syn Fuels Flame Photometer – 14kg (30.8lbs) Shipping – 25kg (55.1lbs) Power requirements 100V – 250V AC at 50 or 60Hz Readout LCD, four line, alpha numeric, back lit. Optimal range Single point calibration Na 0.1 – 60ppm K 0.05 – 100ppm Li 0.05 – 50ppm Ca 1.0 – 100ppm Multi Point Calibration Na 0.1 – 1000ppm K 0.05 – 1000ppm Li 0.05 – 1000ppm Ca 1.0 – 1000ppm Reproducibility <1% Coefficient of variability for 20 consecutive 
 samples over ten minutes at concentrations of 100ppm or less.
 (After instrument stabilisation).Specificity Na/K/Li = <1% to each other when 
 equal in concentration at <100ppmLimit of detection (LOD) and limit 
 of quantification (LOQ) displayedLOD LOQ Na – 0.03ppm Na – 0.1ppm K – 0.02ppm K – 0.05ppm Li – 0.02ppm Li – 0.05ppm Ca – 0.3ppm Ca – 1ppm Time to stability Less than 15 seconds after sample is introduced 
 into the flameIons measured Simultaneous measurement of Na, K, Li, Ca Interfaces USB 0-2.5 volt output (based on sample 
 concentration linked to element of users choice)
 Optional 4-20mA output in place of the above
 Optional integrated printer.CSV and .PDF generated
 reports and files via FP-PC software
 Collection Cup fitted as standard allowing live readingRecommended minimum warm uptime based 
 on ambient temperature21°C – 25 minutes Fuel requirement Propane, Butane or Natural Gas* regulated to 19Bar. 
 Flow rate of 0.4l/min*with modifications. BWB Technologies 
 recommends either Propane or Butane for optimum results.

 
 
 
 
 
            
