AARONIA AG
-
ADASH
-
Amptek
-
AOiP
-
Automatic Research
-
AWSensors
-
BASI
-
BRS
-
CALMET
-
CHECKLINE
-
Cmc
-
CTRL
-
DANATRONICS
-
DV Power
-
Dioxide Materials
-
EA Technology
-
ECH
-
EL-CELL
-
Electrothermal
-
Elsys
-
ELVEFLOW
-
Enapter
-
ENERGY SUPPORT
-
Enervac
-
FASTEC
-
Gaskatel
-
GE
-
GIUSSANI
-
Globecore
-
GMW
-
GREENLIGHT
-
GRZ
-
HIGH SENSE SOLUTIONSHTW
-
HTW
-
HUBER
-
HVPD
-
Ida
-
Instytut Fotonowy
-
IVIUM
-
Jacomex
-
Jenway
-
JGG
-
KEHUA TECH
-
Labdex
-
Labnics
-
LIQUID
-
METERTEST
-
Metrel
-
Microrad
-
micrux
-
ndb
-
Neware
-
Norecs
-
Novocontrol
-
OKOndt Group
-
OZM
-
Pine Research
-
Pinflow
-
Redoxme
-
SATIR
-
Sonel
-
SDT
-
Serstech
-
SENSIA
-
SIKA
-
VacCoat
-
Zurich
- AARONIA AG
- ADASH
- Amptek
- AOiP
- Automatic Research
- AWSensors
- BASI
- BRS
- CALMET
- CHECKLINE
- Cmc
- CTRL
- DANATRONICS
- DV Power
- Dioxide Materials
- EA Technology
- ECH
- EL-CELL
- Electrothermal
- Elsys
- ELVEFLOW
- Enapter
- ENERGY SUPPORT
- Enervac
- FASTEC
- Gaskatel
- GE
- GIUSSANI
- Globecore
- GMW
- GREENLIGHT
- GRZ
- HIGH SENSE SOLUTIONSHTW
- HTW
- HUBER
- HVPD
- Ida
- Instytut Fotonowy
- IVIUM
- Jacomex
- Jenway
- JGG
- KEHUA TECH
- Labdex
- Labnics
- LIQUID
- METERTEST
- Metrel
- Microrad
- micrux
- ndb
- Neware
- Norecs
- Novocontrol
- OKOndt Group
- OZM
- Pine Research
- Pinflow
- Redoxme
- SATIR
- Sonel
- SDT
- Serstech
- SENSIA
- SIKA
- VacCoat
- Zurich
TP Basic / Dryblock-temperature calibrator
型號:Type TP 17450- Compact design for on-site use
- simple calibration without consideration of viscosities, flash points or outgassing
- large calibration volume for simultaneous calibration of several DUT
- optimum thermal coupling from block to DUT due to SIKA calibration inserts
-
Whether for on-site use in the workshop, in the measuring and test room or laboratory, SIKA temperature calibrators can be used everywhere. A wide range of industries and various application areas are covered.
- assembly, commissioning
- manufacturing, production
- maintenance, service
- quality assurance, test equipment monitoring
- repair
Dry block function
The dry block function was developed to enable easy calibration of the temperature in lab and field applications. The optimum thermal coupling from block to DUT is achieved by the correct calibration insert. Ideally, the inner diameter of the bore hole in the calibration insert is 0.5 mm larger than the outer diameter of the DUT. With the help of the calibration insert almost all straight temperature sensors with different lengths and diameters can be calibrated. The dry block covers the entire temperature range without changing the calibration medium. The user does not have to take viscosities, flash points or outgassing into consideration.
-
Temperature range
Room temperature...450 °C
Room temperature...842 °F
Dimension of the calibration insert
Ø 60 x 150 mm (calibration insert easily exchangeable)
Dry block
Display accuracy
±0.6 °C
±1.08 °F
Temperature stability
±0.1 °C
±0.18 °F
Resolution of the temperature display
0.1 °C
0.1 °F
Reference temperature sensor
internal, fixed installation
Dimensions
g Width
g Height
g Depth150 mm
330 + 70 mm (Handle)
270 mmWeight
Approx. 7.5 kg
Power supply
230...240 VAC, 50 / 60 Hz
Power consumption
Approx. 2000 W
Display
Display
2-line, 4-digit digital display red / green, unit °C / °F