AARONIA AG
-
ADASH
-
Amptek
-
AOiP
-
Automatic Research
-
AWSensors
-
BASI
-
BRS
-
CALMET
-
CHECKLINE
-
Cmc
-
CTRL
-
DANATRONICS
-
DV Power
-
Dioxide Materials
-
EA Technology
-
ECH
-
EL-CELL
-
Electrothermal
-
Elsys
-
ELVEFLOW
-
Enapter
-
ENERGY SUPPORT
-
Enervac
-
FASTEC
-
Gaskatel
-
GE
-
GIUSSANI
-
Globecore
-
GMW
-
GREENLIGHT
-
GRZ
-
HIGH SENSE SOLUTIONSHTW
-
HTW
-
HUBER
-
HVPD
-
Ida
-
Instytut Fotonowy
-
IVIUM
-
Jacomex
-
Jenway
-
JGG
-
KEHUA TECH
-
Labdex
-
Labnics
-
LIQUID
-
METERTEST
-
Metrel
-
Microrad
-
micrux
-
TANDELTA
-
ndb
-
Neware
-
Norecs
-
Novocontrol
-
OKOndt Group
-
OZM
-
Pine Research
-
Pinflow
-
Redoxme
-
SATIR
-
Sonel
-
SDT
-
Serstech
-
SENSIA
-
SIKA
-
SMC
-
VacCoat
-
Zurich
- AARONIA AG
- ADASH
- Amptek
- AOiP
- Automatic Research
- AWSensors
- BASI
- BRS
- CALMET
- CHECKLINE
- Cmc
- CTRL
- DANATRONICS
- DV Power
- Dioxide Materials
- EA Technology
- ECH
- EL-CELL
- Electrothermal
- Elsys
- ELVEFLOW
- Enapter
- ENERGY SUPPORT
- Enervac
- FASTEC
- Gaskatel
- GE
- GIUSSANI
- Globecore
- GMW
- GREENLIGHT
- GRZ
- HIGH SENSE SOLUTIONSHTW
- HTW
- HUBER
- HVPD
- Ida
- Instytut Fotonowy
- IVIUM
- Jacomex
- Jenway
- JGG
- KEHUA TECH
- Labdex
- Labnics
- LIQUID
- METERTEST
- Metrel
- Microrad
- micrux
- TANDELTA
- ndb
- Neware
- Norecs
- Novocontrol
- OKOndt Group
- OZM
- Pine Research
- Pinflow
- Redoxme
- SATIR
- Sonel
- SDT
- Serstech
- SENSIA
- SIKA
- SMC
- VacCoat
- Zurich
TP Solid / Dryblock-temperature calibrator
型號:Type TP 281300E- Compact design for on-site use
- simple calibration without consideration of viscosities, flash points or outgassing
- optimum thermal coupling from block to DUT due to SIKA calibration inserts
-
Whether for on-site use in the workshop, in the measuring and test room or laboratory, SIKA temperature calibrators can be used everywhere. A wide range of industries and various application areas are covered.
- assembly, commissioning
- manufacturing, production
- maintenance, service
- quality assurance, test equipment monitoring
- repair
Dry block function
The dry block function was developed to enable easy calibration of the temperature in lab and field applications. The optimum thermal coupling from block to DUT is achieved by the correct calibration insert. Ideally, the inner diameter of the bore hole in the calibration insert is 0.5 mm larger than the outer diameter of the DUT. With the help of the calibration insert almost all straight temperature sensors with different lengths and diameters can be calibrated. The dry block covers the entire temperature range without changing the calibration medium. The user does not have to take viscosities, flash points or outgassing into consideration.
-
Temperature range
400...1300 °C at ambient temperature 20 °C
752 °F...2372 °F at ambient temperature 68 °F
Dimension of the calibration insert
Ø 28 x 200 mm (calibration insert easily exchangeable)
Dry block
Display accuracy
±2 °C
±3.6 °F
Temperature stability
±0.5 °C
±0.9 °F
Resolution of the temperature display
1 °C
1 °F
Reference temperature sensor
internal, fixed installation
Interface
RS485 (calibrator) to USB (PC)
Connectivity
MODBUS
Dimensions
g Width
g Height
g Depth510 mm
290 mm
415 + 100 mm (Handle)Weight
Approx. 17.5 kg
Power supply
100...240 V 50/60 Hz
Power consumption
1000 W
Display
Display
2-line, 4-digit digital display, red / green, unit °C / °F