選擇品牌

-
AstroNova
-
AOiP
-
ADASH
-
Amptek
-
Automatic Research
-
AWSensors
-
AARONIA AG
-
BASI
-
BRS
-
CALMET
-
DV Power
-
DANATRONICS
-
Dioxide Materials
-
ED & D
-
ELVEFLOW
-
ECH
-
Elsys
-
EA Technology
-
Enapter
-
Electrothermal
-
Enervac
-
EL-CELL
-
ENERGY SUPPORT
-
FASTEC
-
GMW
-
Gaskatel
-
GIUSSANI
-
Globecore
-
GRZ
-
HVPD
-
HIGH SENSE SOLUTIONSHTW
-
IVIUM
-
Ida
-
Instytut Fotonowy
-
JGG
-
Jacomex
-
Jenway
-
KEHUA TECH
-
LIQUID
-
Labnics
-
Labdex
-
micrux
-
Metrel
-
Microrad
-
METERTEST
-
ndb
-
Norecs
-
Novocontrol
-
Neware
-
OKOndt Group
-
OZM
-
Pine Research
-
Pinflow
-
Redoxme
-
SATIR
-
Sonel
-
Serstech
-
SDT
-
SENSIA
-
SIKA
-
SMC
-
TANDELTA
-
TENTECH
-
Turnkey Instruments
-
VacCoat
-
Zurich Instruments
- AstroNova
- AOiP
- ADASH
- Amptek
- Automatic Research
- AWSensors
- AARONIA AG
- BASI
- BRS
- CALMET
- DV Power
- DANATRONICS
- Dioxide Materials
- ED & D
- ELVEFLOW
- ECH
- Elsys
- EA Technology
- Enapter
- Electrothermal
- Enervac
- EL-CELL
- ENERGY SUPPORT
- FASTEC
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GRZ
- HVPD
- HIGH SENSE SOLUTIONSHTW
- IVIUM
- Ida
- Instytut Fotonowy
- JGG
- Jacomex
- Jenway
- KEHUA TECH
- LIQUID
- Labnics
- Labdex
- micrux
- Metrel
- Microrad
- METERTEST
- ndb
- Norecs
- Novocontrol
- Neware
- OKOndt Group
- OZM
- Pine Research
- Pinflow
- Redoxme
- SATIR
- Sonel
- Serstech
- SDT
- SENSIA
- SIKA
- SMC
- TANDELTA
- TENTECH
- Turnkey Instruments
- VacCoat
- Zurich Instruments
Flow switches for insertion installation / Metal version for industrial applicat
型號:Type VH780- Universal flow switch for DN 32...200
- Adjustment to nominal diameter and setpoint setting by selection of the baffle flag
- High switching currents due to micro switch as signal transmitter
-
SIKA flow monitors monitor the liquid flow of low-viscosity media in pipelines. Typical applications are:
- heating systems
- cooling circuits
- lubrication circuits
- heat pumps
- water-cooled welding equipment
- compressors
- chemical, pharmaceutical and food industries
- cleaning and environmental protection systems
The flowing medium hits the baffle flag attached to the end of a paddle. The paddle is deflected by the resulting dynamic pressure and actuates a micro switch.
-
Technical data Switching function Change over contact Pressure rating Max. 11 bar (brass)
Max. 30 bar (stainless steel)Temperature ranges Medium -40...120 °C Ambient -40...85 °C (10...90 % rH) Storage and Transportation -40...85 °C, < 95 % rH Electrical data Change over contact
max. contact rating250 VAC, 15 A,
8 A inductive loadDegree of protection EN 60529 IP65 Protection class EN 60730-1 Class I