New 6850 double beam spectrophotometer with variable bandwidth 型號:6850 double beam
  • Double beam spectrophotometer with highly stable optics
  • Variable spectral bandwidth 0.5, 1, 2, 4, 5nm
  • Integrated user interface
  • USB port for data storage
  • Conforms to European Pharmacopeia requirements
  • Jenway Prism PC software included as standard
  • Extensive range of accessories available
    • Double beam spectrophotometer with highly stable optics
    • Variable spectral bandwidth 0.5, 1, 2, 4, 5nm
    • Integrated user interface
    • USB port for data storage
    • Conforms to European Pharmacopeia requirements
    • Jenway Prism PC software included as standard
    • Extensive range of accessories available

    he new 6850 introduces the first double beam spectrophotometer with a variable spectral bandwidth into the Jenway range. The highly stable optics and two detectors measure the sample and reference simultaneously optimising measurement accuracy. The 6850 has measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, kinetics, quantitation, DNA/RNA and protein analysis. 

    Jenway Prism PC software is supplied as standard and offers additional functionality with preloaded methods for DNA/RNA and protein analysis, as well as extensive post-measurement tools, unlimited results saving and easy export of data. 

    The 6850 double beam spectrophotometer is ideal for quality control, general research, pharmaceutical, biochemical and clinical laboratory applications. 

  • Parameter 6850
    Wavelength range 190 to 1100nm
    Wavelength resolution 0.1nm
    Wavelength accuracy ± 0.3nm (at 0.5 and 1nm bandwidth) ± 0.5nm (at 2, 4 and 5nm bandwidth)
    Wavelength reproducibility ± 0.2nm
    Spectral bandwidth Variable 0.5, 1, 2, 4, 5nm
    Photometric range - 0.3 to 3.0A 0 to 200T
    Photometric accuracy ± 0.002A (0- 0.5A) ± 0.3 T (0- 100T)
    Photometric reproducibility ± 0.001 Abs (0 to 0.5 Abs) ± 0.002 Abs (0.5 to 1.0 Abs) 0.15T (0- 100T)
    Resolution 0.1T, 0.001A
    Stray light 0.05T at 220 and 360nm
    Noise 0.0005A
    Stability ± 0.001Ah at 500nm after 15 min warm up
    Multi-wavelength Up to 10 wavelengths, up to 20 wavelengths with PC software
    Calculations Ratio, difference, formulae with factors
    Spectrum range Any range between 190 and 1100nm
    Scan speed 100 to 2000nmmin
    Scan interval 0.1, 0.2, 0.5, 1, 2 or 5nm
    Analysis Auto peaks and valleys, zoom, addition, subtraction, peak ratios, smoothing, wavelength table, derivatives, overlay with PC software
    Kinetics Up to 12 hours with time intervals of 0.1, 0.2, 0.5, 1, 2, 5, 10 or 30 seconds
    Analysis Slope and formula of line of best fit between any two points
    Quantitation points Up to 3 wavelengths
    Quantitation Calibration Blank with up to 10 standards or factor
    Concentration range 0- 99999
    Calibration Blank with standards or factor
    DNA RNA and Protein DNARNA Ratio, concentration, A320 correction
    Light source Tungsten halogen and Deuterium lamps
    Lamp changeover 325 to 370nm selec table
    Outputs USB and parallel
    Operating system: Windows 2000, XP, Vista, Windows 7
    Electrical supply 120VA, 220 110V, 50 60Hz
    Size (w x d x h) 600 x 450 x 200mm